跳至主要内容

博文

目前显示的是 四月, 2020的博文

Medical Face Mask Flame Retardant Tester For Protective Masks Manufacturers

        Medical Face Mask Fire Resistance Tester is mainly used to test the flame retardant performance of medical masks. The combustion performance of the mask is measured through a head mold wearing a mask device to contact with the flame at a certain linear speed.               In the mask flame retardant tester , workers place a mask on the head mold and start the machine on fire.Wearing the mask of the head mold at a speed of 60 mm/second across the high 40 mm, the flame temperature of about 800 degrees Celsius, the surface of the mask because of burning up a little.      Qualified medical surgery, protective masks should have flame retardant performance, and in the specified laboratory conditions, after the removal of the flame fabric continuous combustion time is not more than 5 seconds, that is to say, its short combustion time.Unqualified mask, serious situation can produce a large flame, the afterburn time will be more than 5 seconds. For more information about Medica

Primary Tester For Masks Testing

Masks Synthetic blood penetration tester :The mask material was tested with synthetic blood under continuous applied pressure, and the penetration of synthetic  blood on the material was visually checked.It is useful in establishing claims for penetration resistance performance of medical face masks and ranking their performance.the Mask Synthetic blood penetration test could be done on Synthetic blood penetration tester which is designed to test automatically. Mask flame retardant tester :For the detection of medical protective masks and medical surgical masks, metal head molds and burners are used to simulate the situation where the mask wearer passes in a high-temperature flame to detect the flame retardant effect of the mask.the flame retardant test could be done on mask flame retardant tester. Mask differential pressure tester :Mask differential pressure test:Aiming at the detection of medical surgical masks and disposable medical masks, to verify whether wearing a mask w

What Is Air Exchange Pressure Difference Tester For Medical Face Mask Testing?

    Medical Face Mask Air Exchange Pressure Difference Tester is a lab testing instrument for determination breathability of medica face masks, the test principle is,  through measuring the differential pressure required to draw air through a measured surface area at a constant air flow rate, to test the air exchange pressure of the medical face mask material, which indicates the breathability of medical face masks, tester complies with EN 149, EN 14683, ASTM F2100, MIL-M-36954C,GB 19083, GB 2626, YY/T 0969-2013 medical face masks testing standards.             Medical Face Mask Air Exchange Pressure Difference Tester meets the standard requirements, which is  EN 149, EN 14683, ASTM F2100, MIL-M-36954C,GB 19083, GB 2626 "Medical surgical mask technical requirements"  and YY 0969-2013 "Disposable medical masks", medical face mask air exchange pressure difference tester is measured by gas pressure difference on both sides of  the mask (ie the damping from