How to perform the combustion performance test

In the production of materials burning test is inevitable, remember the recent occurrence of high-rise fire incident, because the material is very poor flame retardation led to a lot of people were killed, the flame retardant materials are some industrial products will check the project, materials The flame retardancy tester is mainly in the specified test conditions to test the burning performance of the specimen to determine the flammability of the material. The following describes the material flame retardant tester product parameters:The main application areas:Plastic, foam, film, textile, paint, rubber, automotive interior parts, electrical and electronic products.

Test principle:The flame retardancy of the material refers to the ability of the material or article to undergo flame burning under specified test conditions. It covers some of the characteristics of whether it is easy to ignite, and the ability to maintain the ability to burn. After years of development, the flame resistance test has formed a variety of standards, as the industry is very focused on the detection project.Testing purposes:Through the customer to provide samples of the combustion test, according to the results of the combustion of the corresponding rating, to help customers to product quality control. Flammability rating is one of the most important safety features that are essential for many certifications and are mandatory for many countries.Test criteria:Plastics - Determination of combustion performance - Horizontal and vertical methods GB / TElectrical and electronic products - Fire hazard test GB / T 5169.16-2008Test Flame 50W Horizontal and Vertical Flame Test MethodGeneral requirements for the safety of information technology equipment GB 4943.1-2011.

Flame resistance test steps:Sampling → pretreatment → start adjustment fixture height, flame height, gas flow, etc. → test and record the results → corresponding to the standard HB rating.HB grade materials should meet one of the following criteria:Remove the ignition source, the material is not visible flame burning;After the ignition source is removed, the sample has a continuous flame burning, but the flame front end does not exceed 100mm mark; if the flame front over 100mm marking, but the thickness of 3.0mm ~ 13.0mm, the linear burning rate of not more than 40mm / Min, or thickness of less than 3.0mm when not more than 75mm / min; if the test thickness of 3.0mm ± 0.2mm sample, the linear burning rate does not exceed 40mm / min, then down to 1.5mm minimum thickness, it should Automatically accepted for this level. 

HB40 grade material should meet one of the following criteria: remove the ignition source, there is no visible flame burning; remove the ignition source, the sample continued flame burning, but the flame front does not reach 100mm mark; if the flame The front end of more than 100mm marking, linear burning rate of not more than 40mm / min.HB75 level: If the flame front over 100mm marking, linear burning rate should not exceed 75mm / min.Through this series of tests on the test piece, the HB properties of the material were obtained

评论

此博客中的热门博文

Tinuvin 1130: An Excellent UV Absorber

 In the field of the chemical industry, UV absorbers play a crucial role, particularly in protecting materials from UV damage. Today, we will delve into a highly regarded UV absorber—Tinuvin 1130. Tinuvin 1130 : chemical name: 3-(3-(2H-benzotriazole-2-yl)-4-hydroxy-5-tert-butyl phenyl)propionic acid polyethylene glycol 300 ester; CAS login number: 104810-48-2. This product is an exceptional UV absorber that offers numerous benefits due to its unique properties. One of the standout features of Tinuvin 1130 is its excellent weather resistance. It has a strong ability to absorb ultraviolet rays, particularly those with wavelengths ranging from 290-400nm. This effectively prevents coatings, plastics, rubber, and other materials from being damaged by UV rays, thereby maintaining the performance and appearance stability of these materials and extending their service life. In addition, Tinuvin 1130 exhibits good compatibility. It is easy to emulsify in water-based systems and can be...

Air-cooled Xenon Lamp Aging Tester

  The air-cooled xenon lamp aging tester is a device that uses an air-cooled system to dissipate heat and a xenon lamp to simulate ultraviolet light, visible light and infrared light in natural sunlight to perform accelerated aging tests on materials. It is commonly used in industries such as automobiles, coatings, plastics, rubber, and textiles. It can evaluate the aging resistance of materials under the combined effects of long-term light, temperature, humidity and other environmental factors in a relatively short period of time, helping companies improve product quality, extend service life, and optimize product anti-aging formulas and processes. Structural composition:  The main body is a test chamber, equipped with a xenon lamp and a matching optical filter system to simulate sunlight of different wavelengths, as well as temperature, humidity, lighting time and other control and adjustment devices, as well as an observation window and a sample rack. Working principle: The...

The Structure of Hexapod Tumble Tester

The Hexapod Tumbler Tester is a popular apparatus used in the evaluation of the appearance retention of carpets. Drum – constructed of Nylon or other like material and capped by a lid that is secured by a latching device. The drum and lid have a locating groove to hold the specimen backing sheet flat to the inner wall of the drum. A photograph of a typical drum is show in Photograph 1 and Photograph 2. The drum dimensions are:   Internal Diameter: 12 ± 0.18 in. (302 ± 5mm) Wall Thickness :0.3 in. approx. (8 mm approx.) Internal Depth: 8.2 ± 0.2 in. (207 ± 5 mm)  Driving System - cradles the drum on rollers and keeps the axis of the drum level, and rotates the drum at 35 ± 2 rpm (3.6 ± 0.2 rad/s). The driving direction reverses after approximately 500 revolutions.  After the 500 rotations the unit will stop and stand stationary for approximately 5 to 15 seconds, then begin rotating in the opposite direction. After 2000 rotations the unit will stop and w...