Characteristics and Precautions of Din Abrasion Tester

Din abrasion resistance tester for elastic materials, rubber, tires, conveyor belts, soles, soft synthetic leather. The The And other materials of the quality of the wear measurement, with high performance, good reproducibility and easy operation of the characteristics. The Din abrasion resistance tester main principle is in a certain load, in a certain level of gauze, the columnar sample on the surface of the gauze across the grinding of a certain trip, by measuring the quality of the sample wear, and then calculated by the density of the sample Volume wear, in order to make the test comparable, and finally the need to use standard rubber, the test results expressed as a calibrated gauze based on the relative volume of wear or foot is expressed as a relative amount of wear Wear base.

Din abrasion tester, also known as drum grinding machine, used to determine the rubber tires, rubber shoes, tape wear resistance, to identify the quality of rubber products. During the test, the rubber material under a certain load and roller gauze on the friction, the determination of the required stroke within the sample wear. Meet GB9867, ISO4649 and DIN53516 requirements. The machine has a small sample, save time, the friction path is not repeated, the advantages of small noise.
DIN abrasion testing machine main issues:test piece can be used DIN drilling machine or standard mold forming, can not be washed test pieces.test piece thickness of not less than 2mm.Test piece thickness greater than 2mm less than 6mm, with a suitable adhesive, stick to a hardness of not less than 80IRHD, Φ16mm material (such as resin), so that the thickness of more than 6mm but their total thickness can not exceed 14mm.If the test material is loose and empty, it is best to stick on a piece of test piece with a hardness of not less than 80IRHD, Φ16mm material (such as resin glue). This allows the test piece can be firmly fixed on the chuck , While the test pieces are not deformed on the chuck, but their total thickness can not exceed 14 mmThe above is the recommended standard, please refer to the relevant standards.standard state of the test piece: before the test stand in the temperature of 23 ℃ ± 2 ℃, the relative temperature of 65 ± 2% of the state in 48 hours or more3. Number of test pieces: the same material to be tested more than three.

评论

此博客中的热门博文

Tinuvin 1130: An Excellent UV Absorber

 In the field of the chemical industry, UV absorbers play a crucial role, particularly in protecting materials from UV damage. Today, we will delve into a highly regarded UV absorber—Tinuvin 1130. Tinuvin 1130 : chemical name: 3-(3-(2H-benzotriazole-2-yl)-4-hydroxy-5-tert-butyl phenyl)propionic acid polyethylene glycol 300 ester; CAS login number: 104810-48-2. This product is an exceptional UV absorber that offers numerous benefits due to its unique properties. One of the standout features of Tinuvin 1130 is its excellent weather resistance. It has a strong ability to absorb ultraviolet rays, particularly those with wavelengths ranging from 290-400nm. This effectively prevents coatings, plastics, rubber, and other materials from being damaged by UV rays, thereby maintaining the performance and appearance stability of these materials and extending their service life. In addition, Tinuvin 1130 exhibits good compatibility. It is easy to emulsify in water-based systems and can be...

Air-cooled Xenon Lamp Aging Tester

  The air-cooled xenon lamp aging tester is a device that uses an air-cooled system to dissipate heat and a xenon lamp to simulate ultraviolet light, visible light and infrared light in natural sunlight to perform accelerated aging tests on materials. It is commonly used in industries such as automobiles, coatings, plastics, rubber, and textiles. It can evaluate the aging resistance of materials under the combined effects of long-term light, temperature, humidity and other environmental factors in a relatively short period of time, helping companies improve product quality, extend service life, and optimize product anti-aging formulas and processes. Structural composition:  The main body is a test chamber, equipped with a xenon lamp and a matching optical filter system to simulate sunlight of different wavelengths, as well as temperature, humidity, lighting time and other control and adjustment devices, as well as an observation window and a sample rack. Working principle: The...

The Structure of Hexapod Tumble Tester

The Hexapod Tumbler Tester is a popular apparatus used in the evaluation of the appearance retention of carpets. Drum – constructed of Nylon or other like material and capped by a lid that is secured by a latching device. The drum and lid have a locating groove to hold the specimen backing sheet flat to the inner wall of the drum. A photograph of a typical drum is show in Photograph 1 and Photograph 2. The drum dimensions are:   Internal Diameter: 12 ± 0.18 in. (302 ± 5mm) Wall Thickness :0.3 in. approx. (8 mm approx.) Internal Depth: 8.2 ± 0.2 in. (207 ± 5 mm)  Driving System - cradles the drum on rollers and keeps the axis of the drum level, and rotates the drum at 35 ± 2 rpm (3.6 ± 0.2 rad/s). The driving direction reverses after approximately 500 revolutions.  After the 500 rotations the unit will stop and stand stationary for approximately 5 to 15 seconds, then begin rotating in the opposite direction. After 2000 rotations the unit will stop and w...