跳至主要内容

The Characteristics of Finger Wear Tester

Product features tend to change over time, the visual appearance is often the consumer to judge the quality of life during the product quality is good or bad. Thus, durability and wear resistance during normal use affect the overall impression of product quality. Damaged surfaces are some of the main causes of poor quality. So in the production of wear testing required, and then an effective evaluation of the product can effectively meet the requirements of consumers, to consumers the feeling of high-quality products.
Finger wear test At present, many instruments exist, such as the electronic button wear test, the current use of more RCA tape wear instrument, the same universal finger wear tester can also be used to measure the electronic button wear test. Below to interpret the universal finger wear tester:Universal finger wear tester:The finger on the surface slides to produce the highest biomechanical feedback when the object interacts with the object. When touching the surface, the fingers are mechanically struck, followed by push-slip motion. In addition to mechanical wear, sweat, body oil, and / or customers are more concerned with the product because the skin may react chemically with the surface of the product and promote further degradation. This combination of mechanical and chemical forces can be tested with TRIBOTOUCH.
Universal finger wear tester is designed to test laboratory samples or finished products under actual conditions of life. The combination of mechanical and chemical stresses produced by finger wear passes the international standard. The TRIBOTOUCH defaults to the biomechanical systems used to accurately reproduce complex fingers from these specifications, and the machine can change the applied pressure or chemical parameters for a product in different situations. This flexibility design allows an instrument to fit into multiple user-defined conditions.
The movement of the piston (artificial finger) is electronically controlled to simulate the wear of the product. Unlike other systems that rarely use pneumatic cylinders, they can wear out over time and give different results. TRIBOTOUCH uses a linear motor every time to ensure accurate application of pressure within the machine's life. The components used to make TRIBOTOUCH are high quality and will ensure high reliability and low maintenance in the next few years.

评论

此博客中的热门博文

Tinuvin 1130: An Excellent UV Absorber

 In the field of the chemical industry, UV absorbers play a crucial role, particularly in protecting materials from UV damage. Today, we will delve into a highly regarded UV absorber—Tinuvin 1130. Tinuvin 1130 : chemical name: 3-(3-(2H-benzotriazole-2-yl)-4-hydroxy-5-tert-butyl phenyl)propionic acid polyethylene glycol 300 ester; CAS login number: 104810-48-2. This product is an exceptional UV absorber that offers numerous benefits due to its unique properties. One of the standout features of Tinuvin 1130 is its excellent weather resistance. It has a strong ability to absorb ultraviolet rays, particularly those with wavelengths ranging from 290-400nm. This effectively prevents coatings, plastics, rubber, and other materials from being damaged by UV rays, thereby maintaining the performance and appearance stability of these materials and extending their service life. In addition, Tinuvin 1130 exhibits good compatibility. It is easy to emulsify in water-based systems and can be...

Chrysler Bending Tester

  Brief Introduction Chrysler bending tester is designed for bending and folding manner by testing base fabric adhesion of the coating material, ie mechanical stability of the coating.  Design Basis Chrysler laboratory test method LP-463LB-9-01.  This test characterizes the degree of adhesion about the vinyl coated fabric and leather fabric coating material. Also it can be vinyl coated fabrics, leather, unsupported rupture, whitening, cracking, lamellar separation of vinyl and other soft furnishings and other materials Product Description: A tester simultaneously tests four samples, including three bend specimens and a folded specimen. When the bending jig sample is clamped at both ends, and taut, holding one end is fixed and the other end of the horizontal movement, the bending test.  The folded ends of the sample close clamped between two opposing plates, a 12lb load is applied in the folding area. If possible, close the flat to exert the appropriate pressure....

Medical Mask Synthetic Blood Penetration Tester

Surgical Masks Synthetic Blood Penetration Resistance Tester Medical Face Mask Synthetic Blood Penetration Resistance Tester is mainly used in the blood penetration test of masks, which ensures that medical masks can have enough protection to prevent the penetration of blood after splashing from bringing danger to users. It is an essential part of mask test, especially for medical masks. Face Mask Synthetic Blood Penetration Resistance Tester can be used not only to detect synthetic blood penetration resistance of medical masks, but also to detect other textile coating materials. When in use, it can be used to detect different directions only by adjusting the appropriate parameters, thus improving the practicability and working efficiency of the equipment to the greatest extent. Mask Synthetic Blood Penetration Tester  Standards: GB 19083-2010 Technical requirements of medical face masks - Anti-penetration property of 5.5 synthetic blood. YY/T 0691-2008 Clothing for protection agai...