跳至主要内容

Fabric Tensile Strength Tester Operating procedures

Universal testing machine operating environment requirements
      
Keep the test environment clean and dry, with the fixture with good oxidation resistance; test machine to work the ambient temperature is 10 ~ 35 ℃, relative humidity of not more than 80%.
Fabric Tensile Strength Tester operation safety requirements
     
1 operator must be the appropriate training, through the assessment before induction.
2 test process operators to concentrate, the test staff can not leave the test site, we must pay close attention to the test changes, the emergence of dangerous conditions to emergency shutdown, in order to avoid personnel safety incidents.
3 clear boot, shutdown sequence: test machine computer printer.
Fabric strength machine operating procedures and methods
1 Preparation before operation:
The tester is reliably grounded and the ground is connected to the rear bolts of the test machine.
Check whether the test sensor meets the test requirements, whether it is necessary to replace the sensor, to avoid excessive damage to the test object test sensor; or because the sensor is too large to exceed the value of the test object is beyond the allowable range.
2 formal operation
Turn on the test machine computer's power switch in sequence (preheat for 15 minutes).
To be tested, place the test bench, adjust the test machine lift button to ensure that the test surface is aligned, and the test fixture.
The computer opens the software to enter the main interface; click on the test part, enter the editing test program interface.
Edit the test program, set the test parameters such as: test items, test force value, limit value; the software in the original test program can be used directly, the new test program need to re-edit and add;
After returning to the main interface, clear the "real-time force value", "displacement", "deformation", and "peak force value".
Click the right triangle button to start the test.
When the "real-time force value" starts to fall and the "real-time force value" is significantly lower than the "peak force value", you can click the box button to stop the test, or use the test machine automatically return to the car (this function required in the test program parameters Set), record the "peak force value" comparison criteria to make the test results to determine.
Remove the test product, the computer exit the software and shut down.
Storage and handling of equipment
1 test machine needs regular dust, with the fixture easy to rust, when not on the oil.
2 test machine start-up after 15 minutes to start the test, if the test half-way shutdown, at least 1 minute after the test machine, can not be shut down directly after the open test machine.
3 If you replace the load sensor, first turn off the test machine power supply, software off-line; and can not be plugged with load sensor lead.
4 test machine at the time of handling, to move horizontally, can not shake too much, but can not move the middle beam (that is loaded with load sensor beam). When the door is careful, do not crush the spot encoder at the top of the test machine.
5 The maximum load of the local load sensor is 10KN (ie 1000 kg) It is important to note that if the test pressure is more than 10KN, write the "load" and "load decay" when setting the "test plan" Two ways to stop.
6 if the use of t software can not control the test machine, first check the test machine and computer connected to the data cable is loose, and then check the software on the line whether the use of com2 serial port (the test machine is com1 serial port).
7 If the software is used, the load window has no force value to see if the connection of the load sensor is loose

评论

此博客中的热门博文

Tinuvin 1130: An Excellent UV Absorber

 In the field of the chemical industry, UV absorbers play a crucial role, particularly in protecting materials from UV damage. Today, we will delve into a highly regarded UV absorber—Tinuvin 1130. Tinuvin 1130 : chemical name: 3-(3-(2H-benzotriazole-2-yl)-4-hydroxy-5-tert-butyl phenyl)propionic acid polyethylene glycol 300 ester; CAS login number: 104810-48-2. This product is an exceptional UV absorber that offers numerous benefits due to its unique properties. One of the standout features of Tinuvin 1130 is its excellent weather resistance. It has a strong ability to absorb ultraviolet rays, particularly those with wavelengths ranging from 290-400nm. This effectively prevents coatings, plastics, rubber, and other materials from being damaged by UV rays, thereby maintaining the performance and appearance stability of these materials and extending their service life. In addition, Tinuvin 1130 exhibits good compatibility. It is easy to emulsify in water-based systems and can be...

Air-cooled Xenon Lamp Aging Tester

  The air-cooled xenon lamp aging tester is a device that uses an air-cooled system to dissipate heat and a xenon lamp to simulate ultraviolet light, visible light and infrared light in natural sunlight to perform accelerated aging tests on materials. It is commonly used in industries such as automobiles, coatings, plastics, rubber, and textiles. It can evaluate the aging resistance of materials under the combined effects of long-term light, temperature, humidity and other environmental factors in a relatively short period of time, helping companies improve product quality, extend service life, and optimize product anti-aging formulas and processes. Structural composition:  The main body is a test chamber, equipped with a xenon lamp and a matching optical filter system to simulate sunlight of different wavelengths, as well as temperature, humidity, lighting time and other control and adjustment devices, as well as an observation window and a sample rack. Working principle: The...

The Structure of Hexapod Tumble Tester

The Hexapod Tumbler Tester is a popular apparatus used in the evaluation of the appearance retention of carpets. Drum – constructed of Nylon or other like material and capped by a lid that is secured by a latching device. The drum and lid have a locating groove to hold the specimen backing sheet flat to the inner wall of the drum. A photograph of a typical drum is show in Photograph 1 and Photograph 2. The drum dimensions are:   Internal Diameter: 12 ± 0.18 in. (302 ± 5mm) Wall Thickness :0.3 in. approx. (8 mm approx.) Internal Depth: 8.2 ± 0.2 in. (207 ± 5 mm)  Driving System - cradles the drum on rollers and keeps the axis of the drum level, and rotates the drum at 35 ± 2 rpm (3.6 ± 0.2 rad/s). The driving direction reverses after approximately 500 revolutions.  After the 500 rotations the unit will stop and stand stationary for approximately 5 to 15 seconds, then begin rotating in the opposite direction. After 2000 rotations the unit will stop and w...