跳至主要内容

Weather Ometer / Xenon Test Chamber Requirements

weather ometer is used to subject articles and finishes to accelerated weathering conditions; for example, a rich ultraviolet source, water spray, or salt water.

 Xenon Test Chamber-A device in which specimen materials can be subjected to artificial and accelerated weathering tests, the effects of sun, rain, and temperature changes; the simulated conditions are usually obtained by the use of electric arcs, water spray, and heating elements.

weather ometer Requirements
Light source: xenon arc lamp 1, power 1500W, life 1000 hours;
Filter glass: a, insulating glass GRBl b, UV glass ZWB2 c, quartz glass tube: diameter 68mm, length 150mm, wall thickness 2mm;
Relative humidity range: 20% ~ 100%;
Spray device: Displacement: 0.09 m3 / h, Exhaust pressure: 2 kg / cm2;
Rainfall: 25W, rainfall: 2 liters / min, rainfall time 0 ~ 4min adjustable
Blackboard temperature range: 40 ℃ ~ 80 ℃ ± 1 ℃;
Accumulated test time: up to 999.9 hours;
Xenon arc lamp working time: can be accumulated, the maximum 999.9 hours
Exposure area: 100mm × 24mm;
Sample frame speed: 5 rev / min, rotation: turn 180 degrees per turn;


Read more on http://www.qinsun-lab.com/

评论

  1. Salt spray machine is used to an accelerated corrosion, it tests the corrosive production and predicts the coating suitability.

    回复删除
  2. Xenon Lamp Weather Resistance Test Chamber, to determine the colorfastness, aging resistance of textiles, plastics, rubber products or materials by objecting to the simulated conditions of nature weather (daylight, rain, temperature, and humidity, etc.). If you want to know more about xenon arc weatherometer testing, please contact us.

    回复删除
  3. Salt Spray Test Chamber is used to test material Corrosion resistance by producing salt fog.

    回复删除

发表评论

此博客中的热门博文

Tinuvin 1130: An Excellent UV Absorber

 In the field of the chemical industry, UV absorbers play a crucial role, particularly in protecting materials from UV damage. Today, we will delve into a highly regarded UV absorber—Tinuvin 1130. Tinuvin 1130 : chemical name: 3-(3-(2H-benzotriazole-2-yl)-4-hydroxy-5-tert-butyl phenyl)propionic acid polyethylene glycol 300 ester; CAS login number: 104810-48-2. This product is an exceptional UV absorber that offers numerous benefits due to its unique properties. One of the standout features of Tinuvin 1130 is its excellent weather resistance. It has a strong ability to absorb ultraviolet rays, particularly those with wavelengths ranging from 290-400nm. This effectively prevents coatings, plastics, rubber, and other materials from being damaged by UV rays, thereby maintaining the performance and appearance stability of these materials and extending their service life. In addition, Tinuvin 1130 exhibits good compatibility. It is easy to emulsify in water-based systems and can be...

Air-cooled Xenon Lamp Aging Tester

  The air-cooled xenon lamp aging tester is a device that uses an air-cooled system to dissipate heat and a xenon lamp to simulate ultraviolet light, visible light and infrared light in natural sunlight to perform accelerated aging tests on materials. It is commonly used in industries such as automobiles, coatings, plastics, rubber, and textiles. It can evaluate the aging resistance of materials under the combined effects of long-term light, temperature, humidity and other environmental factors in a relatively short period of time, helping companies improve product quality, extend service life, and optimize product anti-aging formulas and processes. Structural composition:  The main body is a test chamber, equipped with a xenon lamp and a matching optical filter system to simulate sunlight of different wavelengths, as well as temperature, humidity, lighting time and other control and adjustment devices, as well as an observation window and a sample rack. Working principle: The...

The Structure of Hexapod Tumble Tester

The Hexapod Tumbler Tester is a popular apparatus used in the evaluation of the appearance retention of carpets. Drum – constructed of Nylon or other like material and capped by a lid that is secured by a latching device. The drum and lid have a locating groove to hold the specimen backing sheet flat to the inner wall of the drum. A photograph of a typical drum is show in Photograph 1 and Photograph 2. The drum dimensions are:   Internal Diameter: 12 ± 0.18 in. (302 ± 5mm) Wall Thickness :0.3 in. approx. (8 mm approx.) Internal Depth: 8.2 ± 0.2 in. (207 ± 5 mm)  Driving System - cradles the drum on rollers and keeps the axis of the drum level, and rotates the drum at 35 ± 2 rpm (3.6 ± 0.2 rad/s). The driving direction reverses after approximately 500 revolutions.  After the 500 rotations the unit will stop and stand stationary for approximately 5 to 15 seconds, then begin rotating in the opposite direction. After 2000 rotations the unit will stop and w...