MB3000W solar weather testing machine is widely used in rubber, plastics, paints, paints, petrochemicals, automobiles, textiles and other industries for products and materials to test the color fastness to simulated light by solar radiation, the color fastness to light and perspiration, and light aging. By simulating climatic conditions such as light, rain, spray, light and dark, temperature and humidity, etc., the performance changes such as fading, aging, fading, transmittance, peeling, hardening, and softening of material products are measured.


【Standards compliant】:

Textile: GB/T8430 GB/T12831 GB/T14576 GB/T8427 GB/T1189 GB/T9344 GB 150.7 GB/T16422.1 GB/T1865 GB/T2423.24

Wood-based panels: AATCCTM16 ASTM G26 ASTM D2565 ASTMD4459 ASTM D6695 ASTM G155 SAE J1885 SAE J2412 SAE J2212 SAE J1960 SAE J2527 AATCC169

Automotive interior: ISO105 ASE J1885KJ ISO11341 ISO4892 ISO03917 ISO11341 ISO 4892-2

Leather: PV 1303 PV 3929 PV 3930 DVM 0067- MA HES D6601 NES M0135 TSL 0601G GMW3414 EDS-T-7415 D47 1431



【Instrument Features】:

1. The project was approved by the National Innovation Fund in 2014 and won the National Innovation Award.

2. Adopt 6KW water-cooled long-arc xenon lamp, high-efficiency electric energy and light energy conversion technology, cooperate with high transmittance filter system, and the power of xenon lamp with the same radiation energy is lower, so that the machine can truly realize energy saving and environmental protection.

3. Standard 420nm band monitoring, irradiance digital setting, real-time monitoring, closed-loop automatic adjustment, optional 340nm, 300-400nm, 280-800nm bands.

4. The irradiance uses optical fiber technology to guide light, 16-bit AD sampling, 32-bit ARM processing, digital setting, DC stepless adjustment of xenon lamp, and fully realizes closed-loop stability and automatic compensation.

5. The instrument uses the patented technology of standard lamp calibration, which can completely eliminate the aging attenuation of the irradiance collection system due to long-term tests, patent number: ZL201120297927.8.

6. The black panel thermometer (BPT) and standard black panel thermometer (BST) are tested at the same station (equidistant) with the sample, which truly reflects the test status of the sample; the temperature collection is transmitted by radio frequency technology to reduce the instability caused by mechanical wear.

7. Intelligent circulation adjustment system, ultrasonic and PTC double humidification, circulation wind speed servo motor control, make the temperature, humidity and blackboard temperature in the test chamber realize closed-loop control, and ensure the stable output of test parameters for a long time.



8. The cooling water is mixed with internal circulation and high-energy-efficiency heat exchange system to save water to a higher degree.

9. Super-large experimental chamber design, large-size drum-type sample hanging column, exposure area up to 2660cm2.

10. 10.4-inch color touch screen display control, Chinese and English operation interface, multiple test monitoring modes (animation, digital, curve), multi-segment operation mode programming, support online programming without stopping, convenient operation, intuitive and clear.

11. All sample holders can be timed separately, and different samples can be tested on the same machine, which is convenient for test monitoring and reduces operating costs. The running time and separate timing can be protected against power failure to prevent accidental power failure.

12. The cooling water uses a combination of tap water and recycled waste water to save tap water loss and reduce operating costs.


ps: (WLJCDM809)

https://www.standard-groups.com/en/TextileGarment/

评论

此博客中的热门博文

Tinuvin 1130: An Excellent UV Absorber

 In the field of the chemical industry, UV absorbers play a crucial role, particularly in protecting materials from UV damage. Today, we will delve into a highly regarded UV absorber—Tinuvin 1130. Tinuvin 1130 : chemical name: 3-(3-(2H-benzotriazole-2-yl)-4-hydroxy-5-tert-butyl phenyl)propionic acid polyethylene glycol 300 ester; CAS login number: 104810-48-2. This product is an exceptional UV absorber that offers numerous benefits due to its unique properties. One of the standout features of Tinuvin 1130 is its excellent weather resistance. It has a strong ability to absorb ultraviolet rays, particularly those with wavelengths ranging from 290-400nm. This effectively prevents coatings, plastics, rubber, and other materials from being damaged by UV rays, thereby maintaining the performance and appearance stability of these materials and extending their service life. In addition, Tinuvin 1130 exhibits good compatibility. It is easy to emulsify in water-based systems and can be...

Air-cooled Xenon Lamp Aging Tester

  The air-cooled xenon lamp aging tester is a device that uses an air-cooled system to dissipate heat and a xenon lamp to simulate ultraviolet light, visible light and infrared light in natural sunlight to perform accelerated aging tests on materials. It is commonly used in industries such as automobiles, coatings, plastics, rubber, and textiles. It can evaluate the aging resistance of materials under the combined effects of long-term light, temperature, humidity and other environmental factors in a relatively short period of time, helping companies improve product quality, extend service life, and optimize product anti-aging formulas and processes. Structural composition:  The main body is a test chamber, equipped with a xenon lamp and a matching optical filter system to simulate sunlight of different wavelengths, as well as temperature, humidity, lighting time and other control and adjustment devices, as well as an observation window and a sample rack. Working principle: The...

The Structure of Hexapod Tumble Tester

The Hexapod Tumbler Tester is a popular apparatus used in the evaluation of the appearance retention of carpets. Drum – constructed of Nylon or other like material and capped by a lid that is secured by a latching device. The drum and lid have a locating groove to hold the specimen backing sheet flat to the inner wall of the drum. A photograph of a typical drum is show in Photograph 1 and Photograph 2. The drum dimensions are:   Internal Diameter: 12 ± 0.18 in. (302 ± 5mm) Wall Thickness :0.3 in. approx. (8 mm approx.) Internal Depth: 8.2 ± 0.2 in. (207 ± 5 mm)  Driving System - cradles the drum on rollers and keeps the axis of the drum level, and rotates the drum at 35 ± 2 rpm (3.6 ± 0.2 rad/s). The driving direction reverses after approximately 500 revolutions.  After the 500 rotations the unit will stop and stand stationary for approximately 5 to 15 seconds, then begin rotating in the opposite direction. After 2000 rotations the unit will stop and w...