跳至主要内容
How to use the atomization performance tester for automotive interior materials
The atomization performance tester for automotive interior materials is suitable for the evaluation of the evaporation of volatile components of automotive interior plastics, polyurethane, textiles, leather, adhesives, non-woven fabrics, thermoplastic elastomers, and other materials at high temperatures.
 
As a modern technology enterprise integrating R&D, manufacturing, sales, training, and services, Standard Group (Hong Kong) Co., Ltd. is committed to delivering more testing instruments to the market, providing testing instruments for textiles, leather, combustion, automotive interior and exterior trims, material environmental climate aging, etc., and non-standard customization is also acceptable. Targeted tests can be carried out according to customer requirements before purchase to ensure that the purchased instruments are applicable.
 
Applicable standards:
 
DIN 75201, ISO 6452, ISO 17071, SAEJ1756, QB/T2728, BS EN 14288, PV3920, PV3015, ES-X83231, NESM0161, D451727, GM9305P, TSM0503G

 
Test principle:
 
The sample is heated in the fogging cup and begins to volatilize. The volatile gas condenses on the glass plate or aluminum foil that has been cooled by the cooling chamber. After the condensation process is completed, the glass plate or aluminum foil is removed, and the atomization value or weight of the condensed components of the glass plate or aluminum foil is measured and compared with the data before condensation, so as to obtain the atomization and volatilization characteristics of the sample.
 
Operation:
 
1. Preliminary preparation of the sample
 
2. Open the high and low-temperature baths and reach the set temperature
 
3. Clean the fogging cup and fogging glass plate
 
4. Place the sample
 
5. Place the fogging glass plate or aluminum foil
 
6. Place the cooling chamber
 
7. Maintain the set temperature of the two tanks and operate normally until the required test time
 
8. Remove the glass plate or aluminum foil and leave it for the specified time
 
9. Measure the gloss and haze of the glass plate or the weight of the aluminum foil
 
10. Compare the data and get the final result

Previous: Si4000 Xenon Lamp Aging Tester Six-step Leak Detection


评论

此博客中的热门博文

Tinuvin 1130: An Excellent UV Absorber

 In the field of the chemical industry, UV absorbers play a crucial role, particularly in protecting materials from UV damage. Today, we will delve into a highly regarded UV absorber—Tinuvin 1130. Tinuvin 1130 : chemical name: 3-(3-(2H-benzotriazole-2-yl)-4-hydroxy-5-tert-butyl phenyl)propionic acid polyethylene glycol 300 ester; CAS login number: 104810-48-2. This product is an exceptional UV absorber that offers numerous benefits due to its unique properties. One of the standout features of Tinuvin 1130 is its excellent weather resistance. It has a strong ability to absorb ultraviolet rays, particularly those with wavelengths ranging from 290-400nm. This effectively prevents coatings, plastics, rubber, and other materials from being damaged by UV rays, thereby maintaining the performance and appearance stability of these materials and extending their service life. In addition, Tinuvin 1130 exhibits good compatibility. It is easy to emulsify in water-based systems and can be...

Air-cooled Xenon Lamp Aging Tester

  The air-cooled xenon lamp aging tester is a device that uses an air-cooled system to dissipate heat and a xenon lamp to simulate ultraviolet light, visible light and infrared light in natural sunlight to perform accelerated aging tests on materials. It is commonly used in industries such as automobiles, coatings, plastics, rubber, and textiles. It can evaluate the aging resistance of materials under the combined effects of long-term light, temperature, humidity and other environmental factors in a relatively short period of time, helping companies improve product quality, extend service life, and optimize product anti-aging formulas and processes. Structural composition:  The main body is a test chamber, equipped with a xenon lamp and a matching optical filter system to simulate sunlight of different wavelengths, as well as temperature, humidity, lighting time and other control and adjustment devices, as well as an observation window and a sample rack. Working principle: The...

The Structure of Hexapod Tumble Tester

The Hexapod Tumbler Tester is a popular apparatus used in the evaluation of the appearance retention of carpets. Drum – constructed of Nylon or other like material and capped by a lid that is secured by a latching device. The drum and lid have a locating groove to hold the specimen backing sheet flat to the inner wall of the drum. A photograph of a typical drum is show in Photograph 1 and Photograph 2. The drum dimensions are:   Internal Diameter: 12 ± 0.18 in. (302 ± 5mm) Wall Thickness :0.3 in. approx. (8 mm approx.) Internal Depth: 8.2 ± 0.2 in. (207 ± 5 mm)  Driving System - cradles the drum on rollers and keeps the axis of the drum level, and rotates the drum at 35 ± 2 rpm (3.6 ± 0.2 rad/s). The driving direction reverses after approximately 500 revolutions.  After the 500 rotations the unit will stop and stand stationary for approximately 5 to 15 seconds, then begin rotating in the opposite direction. After 2000 rotations the unit will stop and w...