跳至主要内容

How to operate the Schober abrasion tester

 The Schober abrasion tester uses a rotating wear method to test the appearance changes of fabric samples after friction or wear tests. It is mostly used for automotive interior material testing. During the test, the friction component applies friction to the rotating sample in the tangential direction to measure the wear resistance of the sample.

Shanghai Qianshi Precision Electromechanical Technology Co., Ltd. was established in 2012. It focuses on the research and development, design, and production of textile testing instruments, and provides textile testing instruments and services for academic research units and testing institutions. Shanghai Qianshi is currently one of the most competitive and R&D-capable textile testing instrument manufacturers in China. The R&D team is composed of a group of experienced engineers. We are committed to serving customers wholeheartedly and striving to promote technological innovation in textile testing instruments.


According to standards:


DIN 53863.2, GME Standard 60345, GMW Standard 3283, VW/Audi Zentral-Norm PV 3908, etc.

T106_副本.jpg


Basic principle:


The round specimen is mounted on the rotating test head. The specimen is rubbed against the friction object (sandpaper) in clockwise and counterclockwise directions at a certain speed, pressure, and number of rotations by using rotational wear. The friction object maintains linear contact with the specimen, so a friction effect in the tangential direction can be produced. The rotation direction is changed every 100 frictions (settable). The test results are evaluated by mass loss and the generation of holes.


Operation method:


Use the accessories configured by the instrument to install the temperature and humidity-treated specimen on the specimen fixture to form a rotating test head. Use the arch height test device to adjust the protruding height of the test head according to relevant standards or other specified requirements, generally 5 to 8 mm.


Install the test head with the sample on the test head mounting plate on the instrument workbench, and install and tighten the test head through the positioning pin on the mounting plate and the positioning hole under the test head.


Use the friction fixture on the instrument pressure plate to install the friction sandpaper on the lower surface of the pressure plate, and lock the fixture to ensure that the sandpaper is clamped and installed flat.


Pull the pressure plate lifting lock on the right side of the pressure plate manually to lower the pressure plate so that the sandpaper contacts the surface of the sample on the test head.


Install the weight of the corresponding weight on the weight shaft above the pressure plate (the instrument is equipped with one standard weight of 1500, 1000, 500, 250, 100, and 50g each) to apply a certain pressure to the sample friction. Select the pressure value to be applied according to the weight of the sample per unit area.



评论

此博客中的热门博文

Tinuvin 1130: An Excellent UV Absorber

 In the field of the chemical industry, UV absorbers play a crucial role, particularly in protecting materials from UV damage. Today, we will delve into a highly regarded UV absorber—Tinuvin 1130. Tinuvin 1130 : chemical name: 3-(3-(2H-benzotriazole-2-yl)-4-hydroxy-5-tert-butyl phenyl)propionic acid polyethylene glycol 300 ester; CAS login number: 104810-48-2. This product is an exceptional UV absorber that offers numerous benefits due to its unique properties. One of the standout features of Tinuvin 1130 is its excellent weather resistance. It has a strong ability to absorb ultraviolet rays, particularly those with wavelengths ranging from 290-400nm. This effectively prevents coatings, plastics, rubber, and other materials from being damaged by UV rays, thereby maintaining the performance and appearance stability of these materials and extending their service life. In addition, Tinuvin 1130 exhibits good compatibility. It is easy to emulsify in water-based systems and can be...

Air-cooled Xenon Lamp Aging Tester

  The air-cooled xenon lamp aging tester is a device that uses an air-cooled system to dissipate heat and a xenon lamp to simulate ultraviolet light, visible light and infrared light in natural sunlight to perform accelerated aging tests on materials. It is commonly used in industries such as automobiles, coatings, plastics, rubber, and textiles. It can evaluate the aging resistance of materials under the combined effects of long-term light, temperature, humidity and other environmental factors in a relatively short period of time, helping companies improve product quality, extend service life, and optimize product anti-aging formulas and processes. Structural composition:  The main body is a test chamber, equipped with a xenon lamp and a matching optical filter system to simulate sunlight of different wavelengths, as well as temperature, humidity, lighting time and other control and adjustment devices, as well as an observation window and a sample rack. Working principle: The...

The Structure of Hexapod Tumble Tester

The Hexapod Tumbler Tester is a popular apparatus used in the evaluation of the appearance retention of carpets. Drum – constructed of Nylon or other like material and capped by a lid that is secured by a latching device. The drum and lid have a locating groove to hold the specimen backing sheet flat to the inner wall of the drum. A photograph of a typical drum is show in Photograph 1 and Photograph 2. The drum dimensions are:   Internal Diameter: 12 ± 0.18 in. (302 ± 5mm) Wall Thickness :0.3 in. approx. (8 mm approx.) Internal Depth: 8.2 ± 0.2 in. (207 ± 5 mm)  Driving System - cradles the drum on rollers and keeps the axis of the drum level, and rotates the drum at 35 ± 2 rpm (3.6 ± 0.2 rad/s). The driving direction reverses after approximately 500 revolutions.  After the 500 rotations the unit will stop and stand stationary for approximately 5 to 15 seconds, then begin rotating in the opposite direction. After 2000 rotations the unit will stop and w...